![]() ![]() ![]() The MDS-G4028 Series modular managed ethernet switch supports up to 28 Gigabit ports, including 4 embedded ports, 6 interface module expansion slots, and 2 power module slots to ensure sufficient flexibility for a variety of applications. Each RS-232/422/485 serial port can be configured individually for Modbus RTU or Modbus ASCII operation and for different baudrates, allowing both types of networks to be integrated with Modbus TCP through one Modbus gateway. The MB3660 series can physically manage up to 248 serial slave nodes for 8-port models or 496 serial slave nodes for 16-port models (the Modbus standard only defines Modbus IDs from 1 to 247). For large-scale Modbus deployments, MGate MB3660 gateways can effectively connect a large number of Modbus nodes to the same network. The MGate MB3660 series gateways offer features that make network integration easy, customizable, and compatible with almost any Modbus network. The MGate MB3660 gateways are designed to easily integrate Modbus TCP and RTU/ASCII networks. ![]() The MGate MB3660 series Modbus RTU to Modbus TCP Gateway has isolation models which provides 2 kV isolation protection suitable for power substation applications. ![]() They can be accessed by up to 256 TCP master/client devices, or connect to 128 TCP slave/server devices. The MGate MB3660 (MB3660-8 and MB3660-16) are Modbus RTU to Modbus TCP Gateway, redundant Modbus gateways that convert between the Modbus TCP and Modbus RTU/ASCII protocols. By removing the need to manually create the slave ID routing table, the Auto-Device Routing function saves engineers significant time and cost. A single mouse click is all that’s required to set up a slave ID routing table and configure Modbus gateways to automatically detect Modbus requests from a supervisory control and data acquisition (SCADA) system. Auto-Device Routing for Easy Configuration (Patent Pending) Moxa’s Auto-Device Routing function helps eliminate many of the problems and inconveniences encountered by engineers who need to configure large numbers of Modbus devices. The MB3280 can manage up to 62 serial slave nodes, and the MB3480 can manage up to 124 serial slave nodes. High density, cost effective gateway The MGate™ MB3000 Series Modbus RTU to Modbus TCP gateway converters can effectively connect a high density of Modbus nodes to the same network. The MB3180, MB3280, and MB3480 offer features that make network integration easy, customizable, and compatible with almost any Modbus network. With these models, Modbus serial slave devices can be seamlessly incorporated into an existing Modbus TCP network, and Modbus TCP slaves can be made accessible to serial masters. Standard Modbus network integration, Moxa protocol converter gateway The three standard MGate™ Modbus RTU to Modbus TCP gateway converters (MB3180, MB3280, and MB3480) are designed for easy integration of Modbus RTU to Modbus TCP gateway. For RTU/ASCII masters, up to 32 TCP slaves are supported. Up to 16 simultaneous Modbus TCP masters are supported, with up to 31 RTU/ASCII slaves per serial port. These devices are Modbus RTU to Modbus TCP gateway converter for 1, 2, & 4 Serial ports. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |